Cart (empty) 0

Best sellers

All best sellers

Home

Active filters:

  • Categories: Digital Multimeters
  • Categories: Video Endoscopes
  • Price: $162.00 - $206.00

PeakTech 5600 - Video Borescope

Video Borescope In hobby and professional use, some objects such as terminal ports, electronic components, breaks, constrictions, cracks or other components often must be located and examined in "hard to reach“ locations. This new video borescope-camera offers a number of excellent technical properties, such as the detachable display connected by video cable or the high resolution camera with 6 dimmable LEDs for illumination, which can store photos and videos on a micro SD card. In addition, the diameter of the flexible camera is with only 8,2 mm small enough to get through the smallest vents and gaps. Suitable for all applications, the wide camera viewing angle of 60°, as well as the automatic focus from 30 mm to infinity ensures a clear view of the subject.
$162.24

PeakTech 2710 - Digital Residual Current Devices Tester, RCD Types A, AC

Digital Residual Current Devices Tester, RCD Types A, AC Residual current circuit breakers are used for personal protection and switch off a circuit when a fault current is detected, which flows through the protective earthing (PE). This RCD tester determines the tripping current and the tripping time of residual current circuit breakers which are used in every new building according to current building regulations. The various selectable test currents and characteristics of the RCD allow flexible use of this instrument. RCD testers allow a fault current to flow and determine at which fault current the RCD reacts. Furthermore, the trip time is measured. These two parameters tripping current and tripping time are the safety-relevant characteristics of a residual-current-operated...
$162.67

PeakTech 2715 - Loop/PSC Digital Tester

Loop/PSC Digital Tester PeakTech 2715 Loop/PSC Digital Tester takes two measurements: "LOOP" and "PSC". The "LOOP" function measures the impedance of the circuit between the phase and the earth conductors. If there is a RCD in the circuit, the "LOOP" function can trip it. To limit the test current to 15 mA and prevent the RCD from tripping, use the 2,000 Ω range. A low earth impedance ensures a small contact voltage Uc in the event of a fault. The "PSC" function measures the prospective short-circuit current (PSC) between the phase and the neutral conductors in the event of a short between the two. Knowledge of the PSC allows you to choose the circuit breaker so that it has a breaking capacity higher than the PSC.
$173.52